5.6.24LAU_CONTROL_RESET (0x0207)
Software Reset
This commands resets the software. All software initialization is done. This is not a
hardware reset or a power off/on. The parameter is for protection only. There must
be exactly this two bytes, or else it will answer with a negative acknowledge. This
command never returns a (positive) acknowledge; instead the reset is called.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
This command never returns a (positive) acknowledge.
Response Message (Negative Acknowledge)
Under normal operation conditions, a negative acknowledge message does not con-
tain any status data in response to this command. This response message is only sent,
if there is insufficient data in the command stream.
Maximum Lr for this Command
10
Example
Reset the device at address 1.8 (group 1, address 8):
The device at address 1.8 (group 1, address 8) could not be reset:
0 1 2 3 4 5 6 7...10 11
0x07 ADR
0x4C 0x41 0x55 0x03 ICHKH 0x02 0x07 Param ICHKD
Param
Value: 0xC6A5: This parameter is for protection purposes
Type: Unsigned short
Length: 2
Description: Resets the software
0 1 2 3 4 5 6 7...8 9
0x15 ADR 0x4C 0x41 0x55 0x02 ICHKH 0x02 0x07 ICHKD
0 1 2 3 4 5 6 7...10 11
0x07 0x18
0x4C 0x41 0x55 0x04 0xFA 0x02 0x07 0xA5 0xC6 0x8B
0 1 2 3 4 5 6 7...8 9
0x15 0x18 0x4C 0x41 0x55 0x02 0xEE 0x02 0x07 0xF6