Command Reference
34 Beijer Electronics, MAEN993
5.6.11LAU_CONFIG_GETDEFAULTBRIGHTNESS
(0x0126)
Startup Brightness Mode
For the Beijer Electronics RBCs a default brightness can be stored. This brightness is
used in two cases:
1. To set the display to this brightness when both buttons (brighter and darker) on
the front unit are pressed for about 1 second.
2. When the device is turned on and the startup brightness mode is set to default
brightness.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Get the default brightness of the device at address 0.7 (group 0, address 7):
The default brightness of the device at address 0.7 (group 0, address 7) is returned:
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x26 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0...255
Type: Byte
Length: 1
Description: Returns the default brightness
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x26 0xD8
0 1 2 3 4 5 6 7 8
0x06 0x07
0x4C 0x41 0x55 0x01 0x0F 0x22 0xDD