Beijer-electronics SCOM RBC EN Uživatelský manuál Strana 33

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 64
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 32
Command Reference
Beijer Electronics, MAEN993 33
5.6.10LAU_CONFIG_GETSERIALNUMBER
(0x0125)
Serial Number
Returns the serial number of the device.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
10
Example
Read the serial number of the device at address 0.7 (group 0, address 7):
According to the data returned by the device at address 0.7 (group 0, address 7), its
serial number is 1 (0x0001):
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x25 ICHKD
0 1 2 3 4 5 6 7...8 9
0x06 ADR
0x4C 0x41 0x55 0x02 ICHKH Ret ICHKD
Ret
Value: 0...65535
Type: Unsigned short
Length: 2
Description: The unique serial number
0 1 2 3 4 5 6 7...8 9
0x07 0x07 0x4C 0x41 0x55 0x02 0x0D 0x01 0x25 0xD9
0 1 2 3 4 5 6 7...8 9
0x06 0x07 0x4C 0x41 0x55 0x02 0x0E 0x01 0x00 0xFE
Zobrazit stránku 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 63 64

Komentáře k této Příručce

Žádné komentáře