Command Reference
26 Beijer Electronics, MAEN993
5.6.4 LAU_CONFIG_GETDILMODE (0x010E)
DIL Switch Mode
For a base configuration, Beijer Electronics RBCs are equipped with DIL (DIP)
switches, where the device address and the serial interface mode can be selected. Be-
sides this configuration option, Beijer Electronics RBCs allow full software configu-
ration, which is stored in an internal flash memory. The software configuration also
includes device address and serial interface mode setting. The value returned with
this command indicates whether the device uses hardware settings selected with the
DIL switches, or software settings stored in the internal memory.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Check, whether the device at address 0.7 (group 0, address 7) overrides the DIL set-
tings (i.e. device address and serial interface mode):
According to the data returned by the device at address 0.7 (group 0, address 7), the
device uses DIL settings:
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x0E ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0x00: Device is configured to use the DIL switch settings
0x01: Device is configured to use the software settings
Type: Byte
Length: 1
Description: Indicates whether the device should the DIL switch settings
0 1 2 3 4 5 6 7...8 9
0x07 0x07
0x4C 0x41 0x55 0x02 0x0D 0x01 0x0E 0xF0
0 1 2 3 4 5 6 7 8
0x06 0x07
0x4C 0x41 0x55 0x01 0x0F 0x00 0xFF