Command Reference
40 Beijer Electronics, MAEN993
5.6.15LAU_CONFIG_SETDISPLAYADR (0x018F)
Device Address
Stores a software address of a device in the internal memory. This address is used, if
the device is configured to override the DIL switch settings. Only the address is
changed; not the group.
Supported since Firmware Version
LAUER RBC: 0.0.0.1
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Note:
The changes made by this command will become active only after a restart of the de-
vice. This avoids loosing the connection to the device during configuration.
0 1 2 3 4 5 6 7...9 10
0x07 ADR
0x4C 0x41 0x55 0x03 ICHKH 0x01 0x27 Param ICHKD
Param
Value: 0 ...15 (0x00 … 0x0F)
Type: Byte
Length: 1
Description: Software device address
0 1 2 3 4 5 6 7 8
0x06 ADR 0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0 ...15 (0x00 … 0x0F)
Type: Byte
Length: 1
Description: Software configured device address