iXPanelTA100Service&MaintenanceManualEnglishMAEN013A,2010-12

Strany 2 - Foreword

Installation3Installation3.1 SpaceRequirements• Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)• Space requirements when installing the

Strany 3 - Contents

Installation2.Place the panel cut out where the operator panel is to be situated, draw alongthe outer sides of the holes and cut according to the mark

Strany 4

Installation4.Connect the cables in the specified order, according to the drawing and stepsbelow.Caution:• Ensurethattheoperatorpanelandthecontrollersy

Strany 5 - 1SafetyPrecautions

Installation3.2.1 ConnectionstotheControllerFor information about the cables to be used when connecting the operator panel tothe controller, please re

Strany 6 - 1.5 DismantlingandScrapping

Technical Data4TechnicalDataParameter iX Panel T A100Frontpanel,WxHxD 302x228x6mmMountingdepth 58mm(158mmincludingclearance)Frontpanelseal IP66Rear pa

Strany 7 - 2Introduction

Chemical Resistance5 ChemicalResistance5.1 MetalCasingThe frame and casing material is powder-coated aluminum. This powder paintwithstands exposure to

Strany 8 - 2.4 DismantlingandScrapping

Chemical Resistance5.2 TouchScreenandOverlay5.2.1 AutotexF157/207Autotex F157 or F207 covers the overlay surrounding the touch screen.SolventR esistan

Strany 9 - 2.5 ContactandSupport

Chemical Resistance5.2.2 TouchScreenSurfaceThetouchscreensurfaceonthepanelwithstandsexposuretothefollowingsolvents without visible change:Solvents Tim

Strany 10 - 3Installation

Hardware Tests6 HardwareTestsBefore the operator panels are approved for market introduction, they are testedby independent authorities. The iX Panels

Strany 11 - 0.5 - 1.0 Nm

Hardware Replacement7 HardwareReplacementThis section contains instructions on how to replace operator panel hardware.Only components included in the

Strany 12 - – Connect cable D

ForewordService&MaintenancemanualforiXPanelTA100ForewordThis manual contains detailed information about iX Panel TA100, includingdescriptions of v

Strany 13 - BeijerElectronics, MAEN013A

Hardware Replacement7.2 CablesMostoftheoperatorpanelsusethesametypeofflexcableconnectors.connector flangesFlex cable connectorTo release the flex cables

Strany 14 - 4TechnicalData

Hardware Replacement7.3 ReplacingtheRearCoverThe following is needed:• Anewrearcover,seeAvailable Spare Parts for iX Panel T A100• AtorxT10screwdriver

Strany 15 - 5 ChemicalResistance

Hardware Replacement7.4 ReplacingtheDisplay/DisplayCableThe following is needed:• A ne w display/display c able, see Available Spare Parts for iX Pane

Strany 16 - 5.2 TouchScreenandOverlay

Hardware Replacement5.Remove the mounting plate (9 torx screws). Gently lift the mounting platewith the display and power card.9 x torx screws6.Flip t

Strany 17 - 5.2.3 AutoflexEB

Hardware Replacement7.5 ReplacingtheCompleteFrontThe following is needed:• Anewfront,seeAvailable Spare P arts for iX P anel T A100• AtorxT10screwdriv

Strany 18 - 6 HardwareTests

Hardware Replacement7.6 ReplacingtheBacklightNote:Alllampsinthedisplaymustbereplacedatthesametime.The following is needed:• A ne w backlight, see Avai

Strany 19 - 7 HardwareReplacement

Hardware Replacement7.7 AvailableSparePartsforiXPanelTA100Ordernumber Description601009276 COMPLETEFRONTIncludingfron t cover,touchoverlay,gasketsandl

Strany 20 - 7.2 Cables

Service Menu8ServiceMenuThe service menu for the operator panel can be accessed before a project isdownloaded, or by setting the mode switches in mode

Strany 21 - 7.3 ReplacingtheRearCover

Service Menu8.3.2 Date/TimeUse the Date/Time Settings dialo g to set the time zone, date and time for thepanel.8.3.3 EraseProjectThe erase function wi

Strany 22 - • AtorxT10screwdriver

Hardware Self Test9 HardwareSelfTestThe self test program can be used to test aspects of operator panel functionalityand the communication ports. To r

Strany 23 - 7.4.1 SelfTestoftheDisplay

ContentsContents1 Safety Precautions ... 51.1 General ...

Strany 24 - 7.5 ReplacingtheCompleteFront

Hardware Self Test9.1 SelfTestItemsThe following tests, of which some may be dismissed, are performed:Test itemMaybedismissed PlugRS422(short-circuit)

Strany 25 - 7.6 ReplacingtheBacklight

Additional Installation Tips10 AdditionalInstallationTi psWhen experiencing communication problems in for example noisy environmentsor when operating

Strany 26 - Hardware Replacement

Additional Installation Tips10.2 EthernetConnectioninthePanel123451-12-23-38-8RJ45RJ45RJ45RJ45RJ45RJ45RJ45RJ45Industrial EthernetOperator panelOperato

Strany 27 - 8ServiceMenu

Additional Installation Tips10.3 ToAchieveBetterEMCProtection• Initially, use the original cabling from Beijer Electronics primarily.• Use shielded ca

Strany 28 - 8.3.4 TouchCalibrate

Additional Installation Tips10.4 AmbientTemperatureThe maximum ambient temperature for the operator panel is provided in thespecifications. The ambient

Strany 29 - 9 HardwareSelfTest

Additional Installation Tips10.5 SafetyMost of the operator panels are fed with 24 V DC.412434Power supply230 V AC to 24 V DCPower supply230 V AC to 2

Strany 30 - 9.1 SelfTestItems

Additional Installation Tips10.6 GalvanicIsolationUSBUSBRS232RS422/485+24 V DC0 VFilterDC/DCgalvanic isolationVCC0 V (GND)DC/ACCFLEthernetInternal ele

Strany 31

Additional Installation Tips10.7 CableandBusTerminationRS485• Use shielded and twisted pair cable. The pair capacitance may not e xceed 52.5pF/m and a

Strany 32

Fault Tracing11 FaultTracingThis section includes different fault scenarios and steps to follow to trace the fault.TheiXPanelTA100isnotworkingproperly

Strany 33 - Shielded cable Shielded cable

Fault TracingThetouchscreenismalfunctioningorisnotrespondingatall1.Re-calibrate the touch screen according to the Calibrating the Touch Screen sec-tio

Strany 34 - 10.4 AmbientTemperature

Contents10 Additional Installation Ti ps ... 3110.1 Grounding the Operator Panel ...

Strany 35 - 10.5 Safety

Software12 SoftwareThis chapter describes how to maintain a nd update the software in the iX Panels.The chapter includes a general description of the

Strany 36 - 10.6 GalvanicIsolation

Software12.2 UpdateSoftwareWhen an update is available, an e-mail is sent to the distributors. The software isalso available on the manufacturer’s web

Strany 37 - Inside operator panel

SoftwareRequirementsUpgrading of the operator panel system program requires the following:• APC• An Ethernet connection between the PC and the operato

Strany 38 - 11 FaultTracing

Environmental Aspects13 EnvironmentalAspectsThis chapter includes information about the environmental impact of iX Panels.More information can be foun

Strany 39

Environmental Aspects13.3 RecyclingThe operator panels consist largely of aluminum. It is a great advantage in terms ofboth resources and the environm

Strany 40 - 12 Software

HeadofficeBeijerElectronicsABBox42620124Malmö,Swedenwww.beijerelectronics.com/+4640358600

Strany 41 - 12.2 UpdateSoftware

Safety Precautions1SafetyPrecautionsBoth the installer and the owner and/or operator of the operator panel must readand understand this installation m

Strany 42 - Requirements

Safety Precautions1.3 DuringUse• Keep th e operator panel clean.• Emergency stop and other safety functions may not be controlled from theoperator pan

Strany 43 - 13 EnvironmentalAspects

Introduction2IntroductionThis manual describes how to maintain the iX Panel TA100.The functions available in iX Developer depend on which operator pan

Strany 44 - 13.3 Recycling

Introduction2.2 MaintenanceCarefully read the instructions before beginning maintenance on the operatorpanel.• Only qualified personnel should carry ou

Strany 45 - 20124Malmö,Sweden

Introduction2.5 ContactandSupportIf you want to report a fault or have a question about the operator panels, pleasecontact your local supplier or fill