EPCTA150AMService&MaintenanceManualEnglishMAEN044,2010-12

Strany 2 - Foreword

Installation3Installation3.1 SpaceRequirements• Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)• Space requirements when installing EPC

Strany 3 - Contents

Installation2.Place the panel cut out where the Panel PC is to be situated, draw along theouter sides of the holes and cut according to the markings.3

Strany 4

Installation4.Connect the cables in the specified order, according to the drawing and stepsbelow.Caution:• EnsurethatthePanelPCandthecontrollersystemha

Strany 5 - 1SafetyPrecautions

Technical Data4TechnicalDataParameter EPCTA150AMFrontpanel,WxHxD 398x304x6mmMountingdepth 60mm(160mmincludingclearance)Frontpanelseal IP66Rear panel s

Strany 6 - 1.5 DismantlingandScrapping

Chemical Resistance5 ChemicalResistance5.1 MetalCasingThe frame and casing material is powder-coated aluminum. This powder paintwithstands exposure to

Strany 7 - 2Introduction

Chemical Resistance5.2 TouchScreenandOverlay5.2.1 AutotexF157/207Autotex F157 or F207 covers the overlay surrounding the touch screen.SolventR esistan

Strany 8 - 2.4 DismantlingandScrapping

Chemical Resistance5.2.2 TouchScreenSurfaceThetouchscreensurfaceonthepanelwithstandsexposuretothefollowingsolvents without visible change:Solvents Tim

Strany 9 - 2.5 ContactandSupport

Hardware Replacement6 HardwareReplacementThis section contains instructions on how to replace Panel PC hardware. Onlycomponents included in the latest

Strany 10 - 3Installation

Hardware Replacement6.2 ReplacingtheRearCoverThe following is needed:• Anewrearcover,seeAvailable Spare Parts for EPC TA150 AM• AtorxT10screwdriverNot

Strany 11 - 0.5 - 1.0 Nm

Hardware Replacement6.3 ReplacingtheDisplay/DisplayCableThe following is needed:• A ne w display/display c able, see Available Spare Parts for EPC TA1

Strany 12 - 3.2.1 OtherConnection

ForewordService&MaintenancemanualforEPCTA150AMForewordThis manual contains detailed information about EPC TA150 AM, includingdescriptions of vario

Strany 13 - 4TechnicalData

Hardware Replacement5.Remove the mounting plate (12 torx screws). Gently lift the mounting platewith the display and power card.12 x torx screws6.Flip

Strany 14 - 5 ChemicalResistance

Hardware Replacement1.Press the first calibration point until the Release message appears.Touch calibration pointIf you release the calibration point t

Strany 15 - 5.2 TouchScreenandOverlay

Hardware Replacement6.4 ReplacingtheCompleteFrontThe following is needed:• Anewfront,seeAvailable Spare P arts for EPC T A150 AM• AtorxT10screwdriverN

Strany 16 - 5.2.3 AutoflexEB

Hardware Replacement6.5 ReplacingtheBacklightNote:Alllampsinthedisplaymustbereplacedatthesametime.The following is needed:• Two new backlights, see Av

Strany 17 - 6 HardwareReplacement

Hardware Replacement6.6 AvailableSparePartsforEPCTA150AMOrdernumber Description601009278 COMPLETEFRONTIncludingfront cove r,touchoverlay,gasketsandlab

Strany 18 - 6.2 ReplacingtheRearCover

Additional Installation Tips7 AdditionalInstallationTipsWhen experiencing communication problems in for example noisy environmentsor when operating cl

Strany 19 - BeijerElectronics, MAEN044

Additional Installation Tips7.2 EthernetConnectioninthePanelPC123451-12-23-38-8RJ45RJ45RJ45RJ45RJ45RJ45RJ45RJ45Industrial EthernetPanel PCPanel PCPane

Strany 20

Additional Installation Tips7.3 ToAchieveBetterEMCProtection• Initially, use the original cabling from Beijer Electronics primarily.• Use shielded cab

Strany 21

Additional Installation Tips7.4 AmbientTemperatureThe maximum ambient temperature for the Panel PC is provided in thespecifications. The ambient temper

Strany 22 - 6.4 ReplacingtheCompleteFront

Additional Installation Tips7.5 SafetyMost of the Panel PCs are fed with 24 V DC.412434Power supply230 V AC to 24 V DCPower supply230 V AC to 24 V DCP

Strany 23 - 6.5 ReplacingtheBacklight

ContentsContents1 Safety Precautions ... 51.1 General ...

Strany 24 - Hardware Replacement

Additional Installation Tips7.6 GalvanicIsolationUSBUSBRS232RS422/485+24 V DC0 VFilterDC/DCgalvanic isolationVCC0 V (GND)DC/ACCFLEthernetInternal elec

Strany 25 - 7 AdditionalInstallationTips

Additional Installation Tips7.7 CableandBusTerminationRS485• Use shielded a nd twisted pair cable. The pair capacitan ce may not exceed 52.5pF/m and a

Strany 26

Fault T racing8FaultTracingThis section includes different fault scenarios and steps to follow to trace the fault.TheEPCTA150AMisnotworkingproperly,an

Strany 27 - Shielded cable Shielded cable

Fault T racingThetouchscreenismalfunctioningorisnotrespondingatall1.Re-calibrate the touch screen according to the Calibrating the Touch Screen sec-ti

Strany 28 - 7.4 AmbientTemperature

Software9SoftwareThis chapter describes how to maintain and update the operating system in theEPC TA150 AM, and instructions about how to recover the

Strany 29 - 7.5 Safety

Software9.2 UpdateorCustomizeSoftwareA customized operating system image can be developed with the needs of thecustomer. In this case, please contact

Strany 30 - 7.6 GalvanicIsolation

Environmental Aspects10 EnvironmentalAspectsThis chapter includes information about the environmental impact of the EPCTA150 AM. More information can

Strany 31 - Inside Panel PC

Environmental Aspects10.3 RecyclingThe Panel PCs consist largely of aluminum. It is a great advantage in terms of bo thresources and the environment i

Strany 32 - 8FaultTracing

HeadofficeBeijerElectronicsABBox42620124Malmö,Swedenwww.beijerelectronics.com/+4640358600

Strany 33

Contents10 Environmental Aspects ... 3610.1 General Environmental Aspects ...

Strany 34 - 9Software

Safety Precautions1SafetyPrecautionsBoth the installer and the owner and/or o perator of the Panel PC must read andunderstand this installation manual

Strany 35 - 9.2 UpdateorCustomizeSoftware

Safety Precautions1.3 DuringUse• Keep the Panel PC clean.• Emergency stop and other safety functions may not be controlled from thePanel PC.• Do not u

Strany 36 - 10 EnvironmentalAspects

Introduction2IntroductionThis manual describes how to maintain the EPC TA150 AM.2.1 EPCTA150AMThe following drawings are available for EPC TA150 AM:•

Strany 37 - 10.3 Recycling

Introduction2.2 MaintenanceCarefully read the instructions before beginning maintenance on the Panel PC.• Only qualified personnel should carry out mai

Strany 38

Introduction2.5 ContactandSupportIf you want to report a fault or have a question about the Panel PC, please contactyour local supplier or fill out the

Komentáře k této Příručce

Žádné komentáře